SATEC BFM136 submeter
21 February, 2013 | SATEC (Australia) Pty LtdThe provision of data logging profiling ensures other critical data with date/time stamping is readily available during communication outages. Future proofing for time of use (TOU) for tariff readings on board the meter ensures data is not lost should communication issues transpire with the metering hardware and management software.
Narda Safety Test Solutions IDA-3106 low-frequency loop antenna
21 February, 2013 | Air Met Scientific Pty LtdNarda Safety Test Solutions has extended the range of application for its Interference and Direction Analyzer down to very low frequencies with a new loop antenna. The antenna is particularly suitable for detecting interference caused by switching power supplies or data transmission over electricity supply lines.
SATEC BFM136 multifunction power meter
21 February, 2013 | SATEC (Australia) Pty LtdSATEC’s Branch Feeder Monitor Multifunction Power Meter Series offers metering capabilities for up to 36 current circuits within one device. Retrofit capabilities using split core current transformers make the SATEC BFM136 suitable for energy management solutions for existing commercial buildings, data centres, shopping complexes and hospitals for providing cost allocation for submetering needs.
Schneider Electric TeSys GV3P40 circuit breaker
21 February, 2013 | element14The purpose of TeSys GV3P40 motor circuit breakers is to control and protect 18.5 to 37 kW motors, with voltages up to 690 VAC and a maximum short-circuit breaking capacity of 100 kA.
Brüel & Kjær 4448 personal noise dose meter
21 February, 2013 | TechRentalsThe Brüel & Kjær 4448 Personal Noise Dose Meter assesses noise exposure in the workplace, allowing informed hearing protection level decision-making. Worn on the person, the meter moves with them, monitoring noise exposure related to their individual pattern and work behaviour. It is cable-free and simultaneously measures all relevant parameters required by noise at work standards.
Clevertronics Clever-test self-testing emergency lighting
21 February, 2013 | Clevertronics Pty LtdThe Clevertronics Clever-test range of exit and emergency lighting is designed to provide electrical contractors, specifiers, building owners and occupiers with a cost-effective and thorough means of testing emergency and exit luminaires individually and automatically, in accordance with the mandatory requirements of Australian Standard AS/NZS 2293.2 section 3 ‘Inspection and Maintenance Procedures for Single Point Systems’.
Nutanix OS 3.0 software and NX-3000 series hardware
20 February, 2013 | Matrium Technologies Pty LtdNutanix has announced the latest version of its software, Nutanix OS 3.0, and a hardware line, the NX-3000 series. The products assist enterprises build next-generation, software-defined data centres. In addition to VM-level disaster recovery and adaptive post-process compression, the software also delivers dynamic cluster expansion, rolling software upgrades and support for a second hypervisor, KVM.
Soanar SBS75G 3-pole connector
20 February, 2013 | Soanar LimitedSoanar has added to the Anderson Power Products SBS connector family with the release of the 3-pole SBS75G connector.
Schneider Electric SmartStruxure building management solution
18 February, 2013 | Schneider Electric
Ecopoint LEDisong LED bulb
18 February, 2013 | EcopointThe LEDisong from Ecopoint is the first energy-efficient light bulb that looks and feels like a traditional light bulb, claims the company. Unlike the curly CFL bulbs, the LEDisong is claimed to: be brighter than the average energy-efficient light bulb, use much less power, fit into any light fitting and turn on instantly.
Pfaff-silberblau stainless steel jacks
18 February, 2013 | Motion Technologies Pty LtdSSP stainless jacks are self-locking, with their whirled screw shafts available in any length required. The clevis or head can be standard or made to requirements, again in stainless steel. Two ratios are available (N and L) and the jack can be configured as a travelling screw or a travelling special nut to user dimensions.
Ölflex Solar XLR-R cable
18 February, 2013 | DKSH Australia Pty LtdAS5033.2012 is calling for all DC cabling to be PV1-F compliant. PV1-F is a test criteria from TUV Rheinland which covers the electrical and mechanical properties of the cable. Ölflex Solar XLR-R cable is approved by TUV Rheinland according to 2PfG 1169/08.2007 (PV1-F) and meets all the requirements of AS5033.2012.
Lapp Skintop MS-M Brush cable gland
18 February, 2013 | DKSH Australia Pty LtdLapp Group’s Skintop MS-M Brush has a 360° brush contact design for optimal low-resistance screen contact in a cable gland. With full grounding coverage, the potential for EMI interruptions and equipment failure is eliminated.
DiUS Computing ChargeIQ integrated EV charging system
15 February, 2013 | DiUS Computing Pty LimitedChargeIQ is an integrated software and hardware solution that solves the emerging challenges for the electric vehicle (EV) and electricity industry.